Plug diameter:
11 mm (holding groove approx. 3,4 mm)
Flow air (water)*:
700 - 1500 l/min (10 - 17 l/min)
Function:
Coupled by plugging the plug into the sleeve until you hear a “click”. Pressing the ergonomic plastic release button (for couplings with a tube connection protected against accidental unlocking) releases the plug once again. It is possible to combine coupling plugs and coupling sockets with and without a shut-off valve, and made of different materials as desired. The shut-off valve prevents the medium from spilling out when uncoupled.
Type POM:
Materials:
Body, valves and release button: POM (raw material in accordance with FDA), valve springs: Stainless steel AISI 316, seals: NBR, external spring below push-button: AISI 302, bulkhead nut: nickel-plated brass
Temperature range:
-40°C to max. +80°C
Operating pressure:
-0.8 to 8.3 bar
Media:
Compressed air, water, alcohol, glycol, mineral oils, petrol, oxygen**, carbon dioxide, mild chemicals
Sterilisation possible with:
Formalin, isopropyl alcohol, ethyl alcohol
Operating range:
For general applications. High resistance to mineral oils.
Polypropylene type:
Materials:
Body, valves and release button: polypropylene (raw material in accordance with FDA), valve springs: Stainless steel AISI 316, seals: EPDM, spring below push-button: AISI 302, bulkhead nut: Nickel-plated brass, bulkhead seal: EPDM
Temperature range:
0°C to max. +70°C
Operating pressure:
-0.8 to 7,2 bar (>+27°C observe pressure reductions: +40°C: max. 5,4 bar,+ +50°C: max. 4,3 bar,+ 60°C: max. 3,4 bar,+ +70°C: max 2.0 bar)
Media:
Compressed air, water, many acids and alkaline solutions, alcohol, glycol, MEK, oxygen**, ozone, carbon dioxide, many chemicals
Sterilisation possible with:
Formalin, isopropyl alcohol, ethyl alcohol, ethylene oxide, gamma radiation
Operating range:
Suited for use with many chemicals. Not resistant to mineral oils.
Compatible with****:
CPC Colder APC, CPC Colder EFC12, LinkTech series 50AC, LinkTech series 50PP
Bulkhead thread:
UNS 11/16"-24 (Ø 17.5 mm), max. bulkhead thickness: 12 mm
*When pressure drops by 1 bar (depending on configuration of coupling combination: with/without valve, connection dimension, ... is the flow within the indicated range), **be sure to clean before using with oxygen.
****Names and designations are in part registered trademarks of the respective manufacturers.
{{ $t('shop.all.dokumente') }}: